Performance Indicators:
Main performance of synthetic sleeper for urban rail transportation (CJ/T399-2012/JISE1203-2007)
Item |
Technical Indicator |
|
Bending Strength |
≥70MP |
|
Flexural Modulus of Elasticity |
≥6GP |
|
Longitudinal Compressive Strength |
≥40MP |
|
Shear Strength |
≥7MP |
|
Alternating Current Breakdown Voltage |
≥20k |
|
Surface Resistivity |
≥1×1010 |
|
Amount of Water Absorption |
≤10mg/cm |
|
Flame Retardancy |
HB |
|
Withstand Bending Load |
≥170k |
|
Screw Spike Pulling Strength |
≥40k |
|
Fatigue Resistance |
105 No difference |
|
Density |
0.74±0.10g/c |
|
Weatherability (Xenon Lamp Illumination for 1000h) |
Bending Strength |
≥50MPa |
Flexural Modulus of Elasticity |
≥4.2GP |
|
Longitudinal Compression Strength |
≥30MP |
1. Kebos new-type synthetic sleepers of 300mm thick and below is in dispense with adhesion process, whose thickness is far greater than maximum 70mm of synthetic sleeper blanks by other global manufacturers. This can greatly improve the uniformity and reliability of synthetic rail sleepers.
2. Easy construction: light weight and high strength, convenient to transport and can be cut and punched on site. With easy installation and high precision, it can greatly shorten the construction cycle. According to customer requirements, there can be a variety types of design and processing in order to coordinate with installation.
3. Spike resistance: High spike resistance could ensure the connection of fastener system to be more stable and reliable.
4. Long service life and maintenance-free: Aging resistance with long service life, excellent weather resistance and fatigue resistance.
5. Insulation and waterproof: With good insulation and anti-rust specialties, it can effectively prevent stray current and water erosion.
6. Repairable: It can be repaired on-site through repair agent, the strength after repairment is greater than the original one.